Module 3 Process Piping Hydraulics Sizing And Pressure Rating Pdf May 2026

[ h_f = f \cdot \fracLD \cdot \fracv^22g ]

| Fluid Type | Velocity Range (m/s) | Velocity Range (ft/s) | |------------|----------------------|------------------------| | Pump suction (low NPSH) | 0.6 – 1.5 | 2 – 5 | | Pump discharge (general) | 1.5 – 3.0 | 5 – 10 | | Steam (low pressure) | 20 – 40 | 65 – 130 | | Compressed air | 10 – 25 | 33 – 82 | | Erosive fluids (slurries) | < 3 | < 10 | | Corrosive fluids | < 1.5 | < 5 | [ h_f = f \cdot \fracLD \cdot \fracv^22g

Where ( C ) = empirical constant (100–200 for continuous service), ( \rho_m ) = mixture density (lb/ft³). For liquid piping systems, the optimal pipe diameter balances the cost of the pipe + installation against the lifetime cost of pumping. An empirical formula (Peters & Timmerhaus) gives a first estimate: 3 | &lt