Yfs201 Proteus Library -

void setup() pinMode(2, INPUT_PULLUP); attachInterrupt(digitalPinToInterrupt(2), pulseCounter, RISING); lcd.begin(16, 2); lcd.print("Flow Meter Ready"); delay(2000); lcd.clear(); oldTime = millis();

No dynamic change during simulation unless you script it with VSM Studio. Option B: Use a Potentiometer + Voltage-to-Frequency Converter Model a Hall sensor output using a 555 timer configured as a VCO (voltage-controlled oscillator). Adjust pot to change frequency. Option C: Write Your Own VSM Model Proteus allows custom DLLs (VSM models) in C++. Advanced users can model YFS201 behavior with parameters like min flow, max frequency, and duty cycle. Part 10: Real-World Calibration vs. Simulation The YFS201’s real-world accuracy is ±3% to ±5%. In simulation, it’s perfect. For practical use, calibrate: yfs201 proteus library

Formula: